The Analog Output is a plug-in module designed specifically
for use with the 6510e
Single-Phase Power Analyzer and 6530 Three-Phase Power Analyzer.
It provides up to 12 channels (3 for the 6510e,
12 for the 6530) of analog output corresponding to volts, amps
and watts. Each output is capable of, and calibrated to, ± 10
volts. With the analog output option, the user may apply a scale
factor to all outputs. Amps scaling is applied to all amp channels,
volts scaling is applied to all volt channels and watts scaling
is applied to all watt channels.
Features
- Simple Installation:
Plug-in module automatically configures power analyzer
for operation
- Full Scale Output Range:
± 10V maximum output (user scalable)
- Up to 12 Channels:
6510e Single-Phase Power Analyzer (3 channels),
6530 Three-Phase Power Analyzer (12 channels)
|
- 14-Bit Resolution
- Frequent Output Updates:
Updates every 5 milliseconds
- Output Short Protected
- Factory Calibrated:
Calibration data/values stored on board (EEPROM)
- Industry Standard 25-Pin Connection
|
Applications
The Analog Output can be used along with a 6510e or 6530
Power Analyzer to output information to a strip recorder or
interface with a data acquisition system. The Analog Output
is also used as a safety feature to help trigger alarm events.
| Specifications |
| Resolution |
14 bits |
Temperature
Coefficient |
4 ppm FSR/°C (typical),
20 ppm FSR/°C (maximum) |
| Output Range |
± 10 V maximum |
| Number of Channels |
12 |
| Basic Accuracy |
3 least significant bits |
Output Update Rate
(all channels) |
200 samples/second (5
ms) |
|
| Ordering
Information |
| 6510e |
Single-Phase Power Analyzer |
| 6510e-01 |
Single-Phase Power Analyzer
with Analog Output Option |
| 6530 |
Three-Phase Power Analyzer |
| 6530-01 |
Three-Phase Power Analyzer with
Analog Output Option |
|
|