power analyzer

Magtrol  
 
 
 

Model 6510e/6530 Specifications


Description/Features • Analog Output • External Shunts • Data Sheet  

  VOLTAGE INPUT CURRENT INPUT EXTERNAL SENSOR INPUT POWER
Ranges 30 V, 150 V, 300 V, 600 V 1 A, 5 A, 10 A, 20 A 50 mV, 250 mV, 500 mV, 1.0 V ---
Crest Factor 2.7 @ full scale input 1.7 @ full scale input 2.4 @ full scale input ---
Impedance 2 megohm 12 milliohm 17 kilohm ---
Display Range 5 digits with 10 mV resolution 5 digits with 1 mA resolution 5 digits with 0.1 mV resolution 6 digits with 1 mW resolution
ACCURACY
DC ±(0.1% Reading + 0.2% Range) 0.4% of VA range
5 Hz - 500 Hz ±(0.1% Reading + 0.1% Range) 0.2% of VA range
500 Hz - 10 kHz ±((0.015 × F(kHz)% Reading) + 0.3% Range) 0.6% of VA range
10 kHz - 100 kHz 0.6% + (0.03% × F(kHz)% of VA range)
>100 kHz N/A measurement band limited to DC-100 kHz

FREQUENCY
Source V1,A1, V2,A2, V3,A3, LINE or EXT
(For Vx and Ax, source input must be >10% of range setting)
Accuracy 20 to 500 Hz 0.05%
EXT. Input BNC non-isolated, earth ground referenced
Input Impedance 100 kilohm
Voltage Level TTL / CMOS
Maximum Voltage 50 V

   
 
Top of page go to top of page
Magtrol Inc. (USA): +1-716-668-5555 • magtrol@magtrol.com  |  Magtrol SA (Switzerland): +41 (0)26 407 3000 • magtrol@magtrol.ch
© 1995-2008 Magtrol, Inc.