| For complete technical specifications and general dimension drawings,
download the corresponding data sheet.
For detailed dimension drawings… |
 |
Click on the underlined link in the table below.
A PDF document will open in a new window.
Ratings apply to standard load pins only, special models are available by contacting Magtrol.
| Model(s) |
Nominal
Load |
Nominal
Diameter |
| kN |
tf |
mm |
| LB 210 |
2.5 |
0.28 |
24 |
| LB-LE-LU 211 / LB 231 |
5 |
0.56 |
24 |
| LB-LE-LU 212 / LB 232 |
10 |
1.12 |
24 |
| LB-LE-LU 213 / LB 233 |
20 |
2.25 |
24 |
| LB-LE-LU 214 / LB 234 |
50 |
5.62 |
35 |
| LB 235 |
70 |
7.87 |
45 |
| LB-LE-LU 216 / LB 236 |
100 |
11.24 |
48 |
| LB-LE-LU 217 / LB 237 |
200 |
22.48 |
65 |
| LB-LE-LU 218 / LB 238 |
500 |
56.20 |
89 |
| LB-LE-LU 220 / LB 240 |
1000 |
112.40 |
100 |
| LB-LE-LU 221 / LB 241 |
1250 |
140.50 |
120 |
| Series Ratings |
LB
210
Series |
LB
230
Series |
LE
210
Series |
LU
210
Series |
| Mechanical Characteristics |
| Admissible overload |
150% |
150% |
150% |
150% |
| Overload at rupture |
500% |
500% |
350% to 500%* |
350% to 500%* |
| Electrical Characteristics |
| Bridge
Impedance |
350 ohms |
700 ohms |
5000
ohms |
350 ohms |
| Bridge Configuration |
single |
double |
single |
single |
| Output Signal |
0.5
to 1.8 mV/V |
0.5
to 1.8 mV/V |
4 to 20
mA |
0 to 10
V DC |
| Accuracy (of FSD) |
0.5% to
0.8%* |
< 0.4% |
0.5% to
0.8%* |
0.5% to
0.8%* |
| Power supply |
5 to 12 V DC / AC |
5 to 12 V DC / AC |
12 to 32 VDC
(protected
±) |
12 to 32 VDC
(protected
±) |
| Amplifier |
external |
external |
internal |
internal |
| Output Connection |
PG or
connector |
Connector
only |
Connector
only |
Connector
only |
| Environmental Characteristics |
| Protection class |
IP 66 |
IP 67 |
IP 66 |
IP 66 |
| Operating Temperature |
-25 °C to +80 °C |
| Storage Temperature |
-55 °C to +125 °C |
View/Download
More Information
(printable PDF file) |
|
|
|
|